DRYIT Semi-Continuous Tray Drier
Practical Action
There are two guides on the back cladding to line up the trays centrally over the base.
The guides are fixed to the cladding using wood screws:
Part
Name
Qty Dimensions
-
Woodscrews
25 CSK GALV. ST. No 8 x 15 long
-
Woodscrews
40 CSK GALV. ST. No 10 x 25 long
They are shown in position in figure 19.
Construction
1.) Cut and plane the guides to dimensions shown I the engineering drawing TD016
2) Screw (using countersunk screws, galvanised if available) and glue (waterproof glue) the
guides in position on the cladding side guides and top of finger slots in cladding lined up
before the cladding is fitted to the drying cabinet.
22